Land & Building Experts
PEO COA # 100205934
landbuil
A lighting plan demonstrates the location, height, and type of lighting fixtures on the site and proposed buildings, including the location of electrical supply. A photometric plan demonstrates the lighting fixture locations and illumination levels.
Our licensed professional engineers prepare and certify lighting plans and photometric plans to support site plan applications and to obtain building permits. A lighting plan and photometric plan may be required as part of an application for Site Plan Control. The Planning Act Section 41(7)(a)(5) allows for lighting studies to be requested as part of a site plan approval process. As growth and intensification occur within the municipality in order to meet the future needs of residents and the Provincial Places to Grow Plan, it is important to maintain night time comfort and safe conditions, reduce light pollution, support dark skies and evaluate impacts of new development on surrounding.
Our service area includes all the regions. Counties in Ontario including Toronto (City of Toronto), Hamilton (City of Hamilton), Region of Durham which includes Oshawa (City of Oshawa), Pickering (City of Pickering), Clarington (Municipality of Clarington), Ajax (Town of Ajax), Whitby (Town of Whitby), Brock (Township of Brock), Scugog (Township of Scugog), and Uxbridge (Township of Uxbridge), Region of Halton which includes Burlington (City of Burlington), Halton Hills (Town of Halton Hills), Milton (Town of Milton), and Oakville (Town of Oakville), Region of Peel which includes Brampton (City of Brampton), Mississauga (City of Mississauga), Caledon (Town of Caledon), Region of York which includes Vaughan (City of Vaughan), Aurora (Town of Aurora), East Gwillimbury (Town of East Gwillimbury), Georgina (Town of Georgina), Markham (City of Markham), Newmarket (Town of Newmarket), Richmond Hill (City of Richmond Hill), Whitchurch - Stouffville (Town of Whitchurch-Stouffville), Bradford-West Gwillimbury (Town of Bradford West Gwillimbury) and King (Township of King), Kawartha Lakes (City of Kawartha Lakes), Barrie (City of Barrie), Guelph (City of Guelph), Kitchener (City of Kitchener), Cambridge (City of Cambridge), Waterloo (City of Waterloo)
Excessive and unnecessary site lighting can have a number of detrimental environmental and safety impacts. Specifically, excessive lighting can be inefficient in terms of energy consumption, as well as create glare levels that can be a detriment to drivers, pedestrians and neighbouring properties. From an environmental perspective, the over lighting of towns and cities creates a phenomenon known as Urban Sky Glow, that renders the night sky effectively unviewable to town and city dwellers. Furthermore, poor outdoor lighting design can create light trespass which is a nuisance that negatively affects the enjoyment of a person’s property. The uneven application of lighting standards can create issues around transition; moving from an under lit area to an over lit area. This can have a significant affect on the night vision of drivers, cyclists and pedestrians. The safety issues that pertain to shadowing, peripheral visual detection and clarity of vision, with respect to seeing other people and objects shall be addressed in a lighting plan for a proposed development.
Vertical surface illumination and accent lighting can provide a sense of security and mitigate shadows and provide important aesthetic benefits. All building facades, landscaping and sign lighting should be designed to eliminate direct up lighting from reaching the sky and prevent glare onto neighbouring properties and roadways.
A professional engineer certified lighting plan and photometric plot plan are required to demonstrate a proposed development’s conformity with the applicable policies of the Official Plan, regulations of municipal by-laws and adherence to relevant urban design guidelines, standards and feedback provided at the pre-consultation meeting.
The lighting plan should include the following information
In addition to the requirement for a lighting plan, a photometric plot plan may be required for development proposals located adjacent to sensitive land uses and/or other contexts. Photometric analysis shall be carried out with independent software. The photometric plot plan should include the following information
The purpose of the lighting zones is to recognize the lighting needs for various land uses, while at the same time setting maximum photometric values at the property lines. This will ensure that sites are adequate lighting as well as controlling light trespass.
The land uses that will typically require Lighting Plans & Photometric Plans are
Glare is the sensation produced by a lighting fixture within the visual field that is sufficiently greater than the background brightness to which the eye is adapted to cause discomfort, annoyance or loss in visibility. The control of glare is primarily a function of the light distribution characteristics of the lighting fixture and to some extent the brightness of the surroundings.
Outdoor lighting must be aimed, located, designed, fitted and maintained so as not to present a hazard to drivers, pedestrians or adjacent users by impairing their visibility or create a nuisance by projecting or reflecting objectionable light onto neighbouring properties. All outdoor lighting equipment and fixtures shall be properly shielded and directed downward. Lighting sources are not to be visible from adjacent properties or on-site residential units. Glare control must be achieved through the use of cutoff fixtures, shields and the appropriate application of the fixture mounting height, wattage, aiming angle and fixture placement. For outdoor lighting applications the impact of glare can be contained by limiting the Glare Index as outlined in the IES TM15-07 (Lighting fixture classification system for outdoor lighting fixtures).
Light pollution is considered undesirable and many people feel that it reduces the enjoyment of the night sky. Effective lighting systems must be designed to eliminate direct and indirect skyward lighting. Lighting complaints are frequently due to nuisance glare or excessive brightness in the normal field of vision even though there may be no measurable light at ground level, there is the complaint that, “light is shining in my window.” Such concerns can be addressed by containing light within the design area and carefully selecting, locating and mounting well-shielded lighting fixtures.
Where a property is adjacent to another zone the more restrictive photometric level shall apply at the property line. Where multiple zones exist on the same lot, the zone line shall be treated as property line for the purposes of the lighting plan. Where the Natural Heritage System is within the property line (as identified through an EIS or other document) the photometric level will be required to be met at the limit of Natural Heritage System and/or the property line whatever is greater. For industrial sites or large commercial sites (i.e. 2,000 sq.m. or greater)the maximum pole height may be increased to 7.3 m - check with the municipality's Urban Design Guidelines. Enhanced security applies to lots where night staff may be using the facility (e.g. Hospitals). During periods of non-use, the lighting fixture of certain parking facilities may be turned off or reduced to conserve energy. If reduced lighting is to be used for the purpose of security, the minimum value should not be less than 1.0 lux. Reductions should not be applied to facilities subject to intermittent night use, such as apartments, hospitals and transport terminals. If there are a number of handicap parking spaces, enhanced lighting levels may be used.
Photometric levels provide an effective method of measuring the performance of a lighting design. Photometric uniformity is measured by the ratios Maximum to Minimum and Average to Minimum. These photometric ratios provide a measure of the consistency of lighting across a site and provide assurance that the illuminance is within a range that the human eye can properly discernall objects in its field of view. The following charts indicate the required photometric levels and uniformity ratios for various types of use
Typical Lighting & Photometric Design Criteria
Parking Lots and Loading Areas
Basic(Lux) Enhanced Security (Lux)
Minimum Horizontal 20 (2f.c.) 50 (5f.c)
Illuminance
Uniformity Ratio (Max:Min) 20:1 15:1
Average Vertical Illuminance 10 (1f.c) 25(2.5f.c)
Glare Rating G1
Car Dealerships
Automobiles are typically placed on display adjacent to the roadway and lighting of this area should meet the needs of the business without producing excessive brightness. Lighting should not compromise motorists' visibility on the roadway or that of the customer viewing the merchandise. Lighting fixtures should be placed between the property line the display.
Max Illuminance Uniformity
Horizontal (Lux) (Max:Min)
Adjacent to roadway 200 5:1
Other areas 100 10:1
Entrances 100 5:1
Driveways 30 10:1
Glare rating G2
Private Roads and Driveways
Avg. Horizontal(Lux) Minimum (Lux)
Commercial/Industrial
Driveways 6(0.6f.c) 2 (0.2 f.c.)
Residential/
Institutional
Driveways 4.5(0.4f.c.) 1.5 (0.15 f.c.)
Glare Rating G0
Service Stations (Gas Stations)
Light levels for gas stations should be adequate to facilitate on-site activities without producing excessive brightness. All light fixtures mounted on canopies must be recessed or flush with the bottom surface of the canopy. Areas away from the pumps used for parking or vehicle storage should be designed in accordance with the Outdoor Parking Area Lighting Requirements.
Average Illuminance (Lux)
Approach 20
Driveway 20
Pump island 200
Building facades 30
Service areas 30
Landscape highlights 20
Glare rating G1
Floodlighting Buildings and Monuments
Average Target Illuminance
(Vertical) Lux
Bright surroundings
and light surfaces 50
Bright surroundings
and medium light surfaces 70
Bright surroundings
and dark surfaces 100
Dark surroundings
and light surfaces 20
Dark surroundings
and medium light surfaces 30
Dark surroundings
and dark surfaces 50
Lighting Zones, Spill Light Limitations and Maximum Pole Heights
Ambient Locations Zoning Category Lighting levels Lux-Level Maximum
Brightness at Property Lines Pole Height(m)
Dark Natural Heritage System Wetland 0(0 f.c.) 4.5
Conservation Land at the limit of the
Natural Heritage System
Low Open Space Urban Reserve 2(0.2 f.c) 4.5
Medium Low/medium density Residential 5(0.5 f.c.) 6
Residential Institutional
or Institutional Residential Mixed Use
Park
High Dense Urban with Downtown Zones 7.5(0.75f.c.) 6
Mixed Commercial Residential Apartment
and Industrial Commercial
Industrial
Full Cut-Off Lighting Fixtures:
These lighting fixtures are independently certified by the manufacturers, and do not allow light to be emitted above the lighting fixture. The lighting fixture reduces glare by limiting the light output to less than 10% at and below 10 degrees below the horizontal zoning standard.
Definitions
Candelas - related to luminous flux is luminous intensity. Candelas are the intensity of a lighting fixture in a particular direction. One Lumen = one Candela emitted within a solid angle known as a steradian. (There are 4 pi, or 12.57 steradians in a sphere).Foot candles: Lumens per square foot.
Disability Glare-Glare which impairs the ability to see detail without necessarily causing visual discomfort.
Discomfort Glare-Glare which causes visual discomfort without necessarily impairing the ability to see detail.
Direct Glare-Glare caused when excessive bright light sources in the visual field are seen directly, e.g.: lamps which are inadequately shielded.
Reflected Glare-A term used to describe various visual effects, such as reduction of contrast, discomfort or distraction, produced by reflection of light sources or other bright areas in glossy or semi-matt surfaces.
Illuminance is the amount of light that actually falls on an object. It is the density of light on a particular surface –measured in lux or lumens per square foot (foot candles –fc).
Lamp refers to a bulb or other light producing source.
Light Pollution the overall impact that the lightning of cities and towns has on the night sky.
Light Trespass the projection of light from one site onto another.
Lumens measurement of total amount of light emitted by a bulb, known as luminous flux. A 100-watt incandescent bulb will put out roughly 1,800 lumens, while a high-pressure sodium street lamp of the same wattage will emit about 8,550 lumens.
Luminaire - lighting fixture itself. It is a combination of the bulb, socket, reflectors or lenses, ballast, and housing.
Luminance is the light that the eye sees –i.e., light that has been reflected by a surface. It is measured in Candelas per square foot or metre.Lux:is the measure of illuminance, expressed in units of Lumens per square metre.
Pole Height - Height of a light standard, measured from grade to top tenon cap.
Qualified Lighting Design Professional - Registered Professional Engineer (P.Eng).
Uniformity - Defines the uniformity of light distribution. Measured as maximum: minimum and average: minimum
Most of our outdoor lighting fixtures not only shine where we want them on our streets and buildings, but also up, into the sky. Big cities like Toronto, Mississauga, Brampton, Markham, Richmond Hill, Vaughan, Burlington, Hamilton, Guelph, Cambridge, Kitchener, Waterloo, and London glow intensely, visible testaments to incomplete planning and wasted energy. Lighting is an important component of urban life. Properly designed lighting provides safety and security so the city may be navigated and used at night. Well designed lighting uses energy efficiently and minimizes the negative effects on human and nocturnal animal life. Effective lighting improves the quality of urban life for everyone.
Although artificial lighting has had a positive impact on city life, it has resulted in negative effects where it has been poorly designed or improperly installed. Most types of lighting are beneficial, but glare, light trespass, overlighting and sky glow can actually worsen visibility for city inhabitants.Light pollution is growing faster than the rate of increaseof population. Controlling this wasted light results in energy savings and reduced greenhouse gas emissions. Lighting improvements can pay for themselves in energy savings, sometimes in a matter of months.
Certain animals such as Migratory Birds are negatively affected by lighting at night. For humans, there is growing evidence that lighting at night may be affecting many facets of mental and physical health.
In May 2016, the Province of Ontario approved Official Plan Amendment 262 with respect to the Environmental Policies and Designation of Environmentally Significant Areas, which were adopted by Toronto City Council in November 2015. The new environmental policies included the following additions with regard to light pollution:
3.4.1. To support strong communities, a competitive economy and a high quality of life, public and private city-building activities and changes to the built environment, including public works, will be environmentally friendly, based on:v) mitigating the unacceptable effects of noise and light;
Light pollution in the form of glare, light trespass, over lighting and sky glow can reduce visibility for pedestrians and vehicles and have a negative impact on the health of humans, birds and the natural environment. Light pollution has also drastically limited our view of the stars in the night sky. Properly designed lighting is efficient and effective, providing light exactly where it needs to be for safety and security and results in energy savings and reduced greenhouse gas emissions. Controlling light spillage can also result in darker environments for sleeping, less light at night that may attract migratory birds and less disturbance for fauna natural areas. Effective lighting improves the quality of urban life for everyone.
Contact us Anytime to Prepare the Required Lighting Plans and Photometric Plans.
Typical Lighting Plans and Photometric Plans for Development of Buildings up to 20,000 sq.ft in size would cost $2,485+HST
Call Us Anytime
647 340 8649
Text Messages
416 727 8336
PEO COA # 100205934
Copyright 2015 Land & Building Experts Ltd All rights reserved.
Land & Building Experts
PEO COA # 100205934
landbuil